Egress window size calculator
Enter the open width and height of a bedroom window. The calculator tests the 0.35 m2 area, the 380 mm minimum side, the sill height and the window well clearance from Article 9.9.10.1 of the Ontario Building Code.
Worked example
A casement window with a 600 mm by 700 mm open portion in a basement bedroom, opening into a window well with 600 mm of clearance, gives this result.
- Meets the Building Code figures entered
- Open area (9.9.10.1(1)(b)): Meets the figure. Your open portion is 600 mm (23.6 in) by 700 mm (27.6 in), an area of 0.420 m2 (651 sq in). The Code sets a minimum of 0.35 m2 (542.5 sq in).
- Smallest dimension (9.9.10.1(1)(b)): Meets the figure. Your smaller side is 600 mm (23.6 in). No dimension of the open portion may be less than 380 mm (15.0 in).
- Sill height (9.9.10.1(2)): Meets the figure. The 1,000 mm maximum sill height does not apply to basement areas. Appendix A recommends a sill no higher than 1.5 m above the floor for a basement escape window.
- Window well clearance (9.9.10.1(3)): Meets the figure. Your clearance in front of the window is 600 mm (23.6 in). The Code sets not less than 550 mm (21.7 in), and the sash must not reduce it where it swings into the well (9.9.10.1(4)).
- Smallest open height at your width: 584 mm (23.0 in)
- Smallest open width at your height: 500 mm (19.7 in)
Smallest open height for each open width
At least 0.35 m2 of open area, with no side under 380 mm, means the height has to be at least this much for the width shown.
| Open width | Smallest open height |
|---|---|
| 380 mm (15.0 in) | 922 mm (36.3 in) |
| 400 mm (15.7 in) | 875 mm (34.4 in) |
| 450 mm (17.7 in) | 778 mm (30.6 in) |
| 500 mm (19.7 in) | 700 mm (27.6 in) |
| 550 mm (21.7 in) | 637 mm (25.1 in) |
| 600 mm (23.6 in) | 584 mm (23.0 in) |
| 650 mm (25.6 in) | 539 mm (21.2 in) |
| 700 mm (27.6 in) | 500 mm (19.7 in) |
| 800 mm (31.5 in) | 438 mm (17.2 in) |
| 900 mm (35.4 in) | 389 mm (15.3 in) |
Rules at a glance
| Item | Rule | Section |
|---|---|---|
| Open area | At least 0.35 m2, unobstructed, openable from inside without tools | 9.9.10.1(1) |
| Smallest side | No dimension under 380 mm | 9.9.10.1(1)(b) |
| Sill height | At most 1,000 mm above the floor, except in basement areas | 9.9.10.1(2) |
| Window well | At least 550 mm clearance in front of the window | 9.9.10.1(3) |
| Sliding window | The minimum dimension applies to the openable portion | 9.9.10.1(6) |
Sources and section numbers
- 2024 Ontario Building Code (O. Reg. 163/24), Part 9, Housing and Small Buildings: Article 9.9.10.1, Egress Windows or Doors for Bedrooms.
- 2024 Ontario Building Code (O. Reg. 163/24), Appendix A: explanatory notes to Article 9.9.10.1 on opening areas, sill height, window wells and hopper windows.
Last checked 2026-11-09.
Last checked 2026-11-09 against Article 9.9.10.1 in Part 9 of the 2024 Ontario Building Code (O. Reg. 163/24) and its explanatory notes. This tool is general information, not professional advice. Confirm with Toronto Building or your designer.
Adding a bedroom or a basement suite?
Our design team plans bedroom windows, window wells, ceiling heights and fire safety together, prepares the permit drawings and builds the project, with one point of contact from start to finish.
Andare Homes plans basement renovations and legal basement apartments, including bedroom egress windows, across Toronto and the GTA. Our trades are licensed and insured. Basement renovations, Legal basement apartments, In-law suites.
Frequently asked questions
What size must a bedroom egress window be in Ontario?
Article 9.9.10.1 of the Ontario Building Code requires at least one outside window on every floor level that contains a bedroom in a suite, openable from the inside without tools, with an individual unobstructed open portion of at least 0.35 m2 and no dimension less than 380 mm, that keeps the opening without extra support. Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.
Is a 380 mm by 380 mm window enough?
No. The Code sets 380 mm as the smallest dimension, but the area must still reach 0.35 m2. The explanatory note to Sentence 9.9.10.1(1) says a 380 mm by 380 mm opening would not meet the area requirement. Source: Appendix A of the 2024 Ontario Building Code (O. Reg. 163/24).
How do I measure the open area of a casement or hung window?
Measure the unobstructed open portion with the window fully open, not the glass or the frame. For a single or double hung window only the raised sash opens, so the height is the gap that opens. For a sliding window the 380 mm minimum applies to the openable portion (Sentence 9.9.10.1(6)).
How high can the sill be?
Outside basement areas the window needs a maximum sill height of 1,000 mm above the floor (Sentence 9.9.10.1(2)). The Code sets no maximum sill height for a basement window, and the explanatory note recommends a sill no higher than 1.5 m above the floor with built-in furniture or steps to help access. Source: Appendix A of the 2024 Ontario Building Code (O. Reg. 163/24).
What is the rule for a window well?
Where the window opens into a window well, Sentence 9.9.10.1(3) requires a clearance of not less than 550 mm in front of the window, and a sash that swings toward the well must not reduce that clearance in a way that restricts escape. A protective cover over the well must open from the inside without keys, tools or special knowledge (9.9.10.1(5)). Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.
Does this tool check the basement ceiling height?
No. This calculator tests the window only. Use the basement ceiling height and egress checker for ceiling height and stair headroom.
Cite this tool
Link to this tool from your own page by copying the HTML below.