Basement ceiling height and egress checker
Enter the heights you measured. The checker tests the ceiling, the clearance under beams and ducts and the stair headroom against Part 9 of the Ontario Building Code, and sends you to the egress window calculator for the window.
Worked example
A basement apartment with a 2,000 mm ceiling, a duct with 1,900 mm clear under it and a stair with 1,980 mm of headroom gives this result.
- All 3 checks meet the Building Code figure
- Ceiling height in the suite (9.5.3.1(2)): Meets the figure. You entered 2,000 mm (78.7 in). The Code sets not less than 1,950 mm for ceiling heights in a secondary suite.
- Clear height under beams and ducts in the suite (9.5.3.1(3)): Meets the figure. You entered 1,900 mm (74.8 in). The Code sets not less than 1,850 mm under beams and ducting in a secondary suite.
- Clear height over the stairs (9.8.2.2(3)): Meets the figure. You entered 1,980 mm (78.0 in), measured vertically from the line through the tread nosings. The Code sets not less than 1,950 mm over stairs serving a single dwelling unit or a house with a secondary suite, and 1,850 mm under beams and ducting in a secondary suite (9.8.2.2(4)).
Heights at a glance
| Space | Minimum | Section |
|---|---|---|
| Basement of a house without a secondary suite | 2,100 mm over at least 75% of the basement area; 1,950 mm under beams and ducts | Table 9.5.3.1 |
| Bedroom in that basement | 2,300 mm over at least 50% of the required area, or 2,100 mm over all of it; floor under 1,400 mm does not count | Table 9.5.3.1 |
| Ceiling in a secondary suite | 1,950 mm | 9.5.3.1(2) |
| Under beams and ducting in a secondary suite | 1,850 mm | 9.5.3.1(3) |
| Over stairs serving one dwelling unit or a house with a secondary suite | 1,950 mm; 1,850 mm under beams and ducting in a secondary suite | 9.8.2.2(3) and (4) |
| Over stairs in other buildings | 2,050 mm | 9.8.2.2(2) |
Sources and section numbers
- 2024 Ontario Building Code (O. Reg. 163/24), Part 9, Housing and Small Buildings: Table 9.5.3.1 and Article 9.5.3.1 (ceiling heights), Article 9.8.2.2 (height over stairs).
- City of Toronto, When do I need a building permit?: underpinning and excavation need a permit.
Last checked 2026-11-09.
Last checked 2026-11-09 against Table 9.5.3.1, Article 9.5.3.1 and Article 9.8.2.2 in Part 9 of the 2024 Ontario Building Code (O. Reg. 163/24). This tool is general information, not professional advice. Confirm with Toronto Building or your designer.
Planning a basement renovation or a legal basement apartment?
Our design team measures your basement, plans ceiling heights, stairs and egress together, prepares the permit drawings and builds the project, with one point of contact from start to finish.
Andare Homes finishes basements, builds legal basement apartments and carries out basement underpinning across Toronto and the GTA. Our trades are licensed and insured. Basement renovations, Legal basement apartments, Basement underpinning.
Frequently asked questions
How high must a basement ceiling be in Ontario?
For a basement in a house without a secondary suite, Table 9.5.3.1 of the Ontario Building Code asks for 2,100 mm over at least 75% of the basement area, with the clearance under beams and ducts allowed to drop to 1,950 mm. In a secondary suite, Sentences 9.5.3.1(2) and (3) set ceiling heights of not less than 1.95 m and clear heights under beams and ducting of not less than 1.85 m. Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.
Where do I measure the ceiling height?
Measure from the finished floor to the underside of the finished ceiling, after any drop ceiling, flooring or insulation is added. The note to Table 9.5.3.1 says the area of a space is measured at floor level, so the share of floor area that has the required height is counted on the floor, not on the ceiling.
How much headroom does a basement stair need?
Sentence 9.8.2.2(3) sets the clear height over stairs serving a single dwelling unit or a house with a secondary suite, including their common spaces, at not less than 1,950 mm, measured vertically from a line tangent to the tread and landing nosings. Under beams and ducting in a secondary suite the figure is 1,850 mm (9.8.2.2(4)). Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.
What changes if there will be a bedroom in the basement?
For a bedroom in a house without a secondary suite, Table 9.5.3.1 asks for 2,300 mm over at least 50% of the required floor area, or 2,100 mm over all of it, and floor with a clear height under 1,400 mm does not count toward the required area. A bedroom also needs an escape window: Article 9.9.10.1 sets the window size, and our egress window size calculator tests it.
My basement is too low. What can be done?
Lowering a basement floor by underpinning, or excavating, is listed by the City of Toronto as work that needs a building permit, and it is designed by an engineer. Source: City of Toronto, When do I need a building permit?. Our basement underpinning team can assess the options for your house.
Does this tool design my basement?
No. It compares the heights you measure with the figures in the Building Code. The building department decides, so confirm with Toronto Building or your designer before you dig, lower a floor or finish the space.
Cite this tool
Link to this tool from your own page by copying the HTML below.