Quote-Ready Now In-House Design Team Licensed and Insured
Free tool

Stair calculator for Ontario

Enter the total rise from floor to floor. The calculator shows how many risers the Ontario Building Code allows, the rise and run of each option, and tests the run you have, the headroom and the stair width.

Work out your stair

Optional. The horizontal length you have for the stair.
Optional.
Optional.

Worked example

A private stair with a 2,600 mm total rise, 3,500 mm of run, 1,980 mm of headroom and a 900 mm width gives this result.

  • Stair fits: 13 risers
  • Total rise: 2,600 mm (102.4 in)
  • Stair type: Private stairs, inside or outside a house or dwelling unit: rise 125 to 200 mm, run 255 to 355 mm (Table 9.8.4.1)
  • Number of risers allowed: 13 to 20 (rise between 125 mm and 200 mm)
  • Option 1: 13 risers of 200.0 mm (7.87 in), 12 treads, run 291.7 mm each: meets the figure
  • Option 2: 14 risers of 185.7 mm (7.31 in), 13 treads, run 269.2 mm each: meets the figure
  • Option 3: 15 risers of 173.3 mm (6.82 in), 14 treads, run 250.0 mm each: run too short
  • Option 4: 16 risers of 162.5 mm (6.40 in), 15 treads, run 233.3 mm each: run too short
  • Run available: 3,500 mm (137.8 in)
  • Flight height (9.8.3.3): A single flight may rise up to 3.7 m. This rise is within that figure.
  • Headroom over the stair (9.8.2.2): Meets the figure. 1,980 mm (78.0 in) against 1,950 mm (76.8 in), measured vertically from the line through the tread nosings. Under beams and ducting in a secondary suite the Code allows 1,850 mm (9.8.2.2(4)).
  • Stair width (9.8.2.1): Meets the figure. 900 mm (35.4 in) against 860 mm (33.9 in).

Stair figures at a glance

Stair typeRiseRun (rectangular treads)HeadroomWidth
Private stairs125 to 200 mm255 to 355 mm1,950 mm860 mm
Public stairs, residential building125 to 180 mm280 mm or more2,050 mm900 mm
SectionTable 9.8.4.1Table 9.8.4.19.8.2.29.8.2.1

A single flight may rise up to 3.7 m (9.8.3.3). Risers are uniform within 5 mm between adjacent treads and 10 mm across the flight (9.8.4.4).

Sources and section numbers

Last checked 2026-11-09.

Last checked 2026-11-09 against Table 9.8.4.1 and Articles 9.8.2.1, 9.8.2.2, 9.8.3.3 and 9.8.4.4 in Part 9 of the 2024 Ontario Building Code (O. Reg. 163/24). This tool is general information, not professional advice. Confirm with your designer or Toronto Building.

Planning new stairs or a staircase relocation?

Our design team plans the staircase with the floor plan, headroom and railings, prepares the permit drawings where they are needed and builds it, with one point of contact from start to finish.

Andare Homes builds custom stairs and railings and plans staircases into basement renovations, additions and whole-home renovations across Toronto and the GTA. Our trades are licensed and insured. Custom stairs and railings, Basement renovations, Home additions.

Frequently asked questions

What are the stair rise and run limits in the Ontario Building Code?

Table 9.8.4.1 sets, for private stairs, a rise of 125 mm to 200 mm and, for rectangular treads, a run of 255 mm to 355 mm. For public stairs the rise is 125 mm to 180 mm and the run is not less than 280 mm. Private stairs are the interior and exterior stairs of a house with a secondary suite or an individual dwelling unit, and exterior stairs to a garage that serves one. Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.

How many risers do I need for my total rise?

Divide the total rise by the largest allowed rise and round up to get the fewest risers, then divide by the smallest allowed rise, 125 mm, and round down to get the most. A total rise of 2,600 mm divided by 200 mm gives 13 risers at the fewest, so each riser would be exactly 200 mm. A flight normally has one tread fewer than risers, because the upper floor acts as the last tread.

How much headroom does a stair need?

Sentence 9.8.2.2(3) sets not less than 1,950 mm for stairs serving a single dwelling unit or a house with a secondary suite, including their common spaces, and 9.8.2.2(2) sets 2,050 mm for other stairs. Under beams and ducting in a secondary suite the figure is 1,850 mm (9.8.2.2(4)). It is measured vertically from a line tangent to the tread and landing nosings. Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.

How wide must a stair be?

Exit stairs serving a single dwelling unit or a house with a secondary suite, including their common spaces, are not less than 860 mm wide (9.8.2.1(2)). At least one stair between each floor level inside a dwelling unit also has a width of not less than 860 mm (9.8.2.1(4)). Required exit stairs and public stairs in a residential building are not less than 900 mm wide (9.8.2.1(1)). Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.

How tall can one flight of stairs be?

Article 9.8.3.3 says the vertical height of any flight of stairs shall not exceed 3.7 m, so a taller rise needs a landing that splits it into more than one flight. Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.

Do all the risers have to be exactly the same?

Article 9.8.4.4 requires risers in a flight to be uniform within 5 mm between adjacent treads and within 10 mm between the tallest and shortest risers in the flight. Rectangular treads must have a uniform run within the same tolerances. Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.

Cite this tool

Link to this tool from your own page by copying the HTML below.

See all of our free tools

Planning a renovation?

Tell us about your project and our design team will get back to you.

Free, no-obligation consultation and site visit with our design team.

or
Call (416) 524-1165
Call now (416) 524-1165 Book a Consultation