Enter the height of your deck above the ground. The checker shows whether the City of Toronto lists a permit, whether a guard is required, the minimum guard height, the opening limit and the stair handrail rule.

Check your deck

Measured from the adjacent finished grade to the top of the deck surface.
Optional. Whole number.
Optional.
Optional.

Worked example

A deck 900 mm above the ground, attached to the house, without a roof, with 4 stair risers, a planned 900 mm guard and a 90 mm picket gap gives this result.

  • Permit needed
  • Deck height above grade: 900 mm (35.4 in)
  • Building permit: Needed
  • Guard required (9.8.8.1(1)): Yes, on each side that is not protected by a wall, because the drop within 1.2 m is more than 600 mm
  • Minimum guard height (9.8.8.3): 900 mm (35.4 in): exterior guards serving one dwelling unit, or a house with a secondary suite, where the walking surface is not more than 1,800 mm above the ground
  • Guard openings (9.8.8.5): Openings must stop a sphere 100 mm in diameter from passing through. Triangular openings at stairs must stop a 150 mm sphere.
  • Guards that do not help climbing (9.8.8.6): No member, attachment or opening between 140 mm and 900 mm above the deck surface should facilitate climbing, unless the location and size of the openings can be shown to be no hazard.
  • Your planned guard height: Meets the figure. 900 mm (35.4 in) against 900 mm (35.4 in).
  • Your planned opening between pickets: Meets the figure. 90 mm (3.5 in): the opening has to be small enough to stop a 100 mm sphere, so keep it under 100 mm.
  • Stair handrail (9.8.7.1(4)): Exterior stairs with more than 3 risers need at least one handrail where the deck serves one dwelling unit or a house with a secondary suite. Required handrails are 865 mm to 1,070 mm high (9.8.7.4(2)).

Rules at a glance

ItemRuleSource
Building permitNeeded for a deck more than 60 cm (24 in) above ground; an unroofed platform at or under 60 cm, not part of a required exit, is listed as not needing oneCity of Toronto permit list
Guard requiredWhere the drop within 1.2 m of the walking surface is more than 600 mm9.8.8.1(1)
Guard height900 mm up to 1,800 mm above ground for one dwelling unit or a house with a secondary suite; 1,070 mm above that9.8.8.3
OpeningsStop a 100 mm sphere; stair triangles stop a 150 mm sphere9.8.8.5
ClimbingNo member or opening between 140 mm and 900 mm that facilitates climbing9.8.8.6(1)
Stair handrailNot required up to 3 risers; one handrail above 3 risers; 865 mm to 1,070 mm high9.8.7.1(3), (4); 9.8.7.4(2)

Sources and section numbers

Last checked 2026-11-09. A deck must also meet the Zoning By-law, which sets how close it can be to the lot lines.

Last checked 2026-11-09 against the City of Toronto permit list, the City deck application guide and Part 9 of the 2024 Ontario Building Code (O. Reg. 163/24). This tool is general information, not professional advice. Toronto Building decides, so confirm before you build.

Planning a new deck?

Our design team plans the deck, stairs and guards together, prepares the permit drawings and builds the project, with one point of contact from start to finish.

Andare Homes designs and builds decks and outdoor living spaces, with stairs and guards, and custom stairs and railings across Toronto and the GTA. Our trades are licensed and insured. Decks and outdoor living, Custom stairs and railings.

Frequently asked questions

How high can a deck be before it needs a permit in Toronto?

The City of Toronto lists constructing a deck more than 60 cm (24 inches) above ground as needing a building permit. It lists an unroofed platform as not needing one when its finished deck level is not more than 60 cm above the adjacent finished grade, it is not part of an exit required under the Building Code and it complies with the Zoning By-law. Source: City of Toronto, When do I need a building permit?.

Does a low deck attached to the house need a permit?

The City's deck application guide describes a building permit review for a deck, veranda or porch to an existing house and notes that some detached decks may not need a permit. Because the City's exemption list and its deck guide are worded differently for a deck attached to a house, this tool shows an attached low deck as "It depends". Confirm with Toronto Building before building. Source: City of Toronto, Decks and Porches.

When does a deck need a guard?

Sentence 9.8.8.1(1) of the Ontario Building Code requires a guard on each side of a walking surface that is not protected by a wall, for the length where the difference in elevation is more than 600 mm between the walking surface and the adjacent surface within 1.2 m. Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.

How high must a deck guard be?

Exterior guards serving not more than one dwelling unit, or a house with a secondary suite, must be not less than 900 mm high where the walking surface is not more than 1,800 mm above the finished ground. Above that height the general figure of 1,070 mm applies, and 1,500 mm applies to exterior stairs and landings more than 10 m above the ground (Article 9.8.8.3). Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.

How far apart can the pickets be?

Openings through a required guard must stop a sphere 100 mm in diameter from passing, so the gap between pickets has to be under 100 mm. The triangular openings at a stair must stop a 150 mm sphere (Article 9.8.8.5). Required guards must also be designed so that no member, attachment or opening between 140 mm and 900 mm above the deck surface facilitates climbing, unless the location and size of the openings can be shown to be no hazard (Article 9.8.8.6). Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.

Do deck stairs need a handrail?

Handrails are not required on exterior stairs serving a single dwelling unit that have not more than 3 risers (Sentence 9.8.7.1(3)). Exterior stairs with more than 3 risers need at least one handrail where they serve not more than one dwelling unit or a house with a secondary suite (9.8.7.1(4)), at 865 mm to 1,070 mm high (9.8.7.4(2)). Source: 2024 Ontario Building Code (O. Reg. 163/24), Part 9.

Cite this tool

Link to this tool from your own page by copying the HTML below.

See all of our free tools

Planning a renovation?

Tell us about your project and our design team will get back to you.

Free, no-obligation consultation and site visit with our design team.

or
Call (416) 524-1165
Call now (416) 524-1165 Book a Consultation