Accessible ramp and doorway calculator
Find the ramp length a given rise needs, check an existing slope, or test a doorway width, using the figures in Section 3.8 of the Ontario Building Code.
Last checked 2026-11-08 against Articles 3.8.1.1, 3.8.3.3 and 3.8.3.4 of the 2024 Building Code Compendium. Section 3.8 does not apply to every type of house, so treat the results as a benchmark and confirm with your designer or the building department. This tool is general information, not professional advice.
Planning an accessibility renovation?
Our design team plans ramps, wider doorways, bathrooms and entrances together, handles the permit drawings and builds the project, with one point of contact from start to finish.
Frequently asked questions
What is the steepest ramp the Ontario Building Code allows?
Article 3.8.3.4 of the Ontario Building Code says a ramp in a barrier-free path of travel has a maximum gradient of 1 in 12. That means 12 units of run for every 1 unit of rise, so a 600 mm rise needs at least 7,200 mm of ramp. It also says floors or walks in a barrier-free path of travel with a slope steeper than 1 in 20 are designed as ramps. Source: Ontario 2024 Building Code Compendium, Part 3.
How wide must a barrier-free ramp be?
Article 3.8.3.4 sets a minimum width of 1,000 mm between handrails for a ramp in a barrier-free path of travel. Handrails are required on both sides, between 865 mm and 965 mm high, extending horizontally at least 300 mm beyond the top and bottom of the ramp. Source: Ontario 2024 Building Code Compendium, Part 3.
Where do landings go on a ramp?
Article 3.8.3.4 requires a level area of at least 1,700 mm by 1,700 mm at the top and bottom of a ramp, and a level area at least 1,700 mm long and at least as wide as the ramp at intervals of not more than 9 m along its length and where the ramp changes direction by 90 degrees or more. Source: Ontario 2024 Building Code Compendium, Part 3.
How wide must a doorway be in a barrier-free path of travel?
Article 3.8.3.3 requires a clear width of not less than 850 mm with the door in the open position. Inside a residential suite, the doorway to at least one bathroom and to each bedroom on the same level must have a clear width of at least 760 mm when the door is served by a corridor or space at least 1,060 mm wide, and 810 mm when the corridor or space is narrower than 1,060 mm. There are exceptions, so confirm the details for your project. Source: Ontario 2024 Building Code Compendium, Part 3.
Does Section 3.8 apply to my house?
Article 3.8.1.1 says Section 3.8 applies to all buildings except several types, including detached houses, semi-detached houses, houses with a secondary suite, duplexes, triplexes, townhouses and row houses. So these numbers are a recognised benchmark for a home accessibility project, but they may not be a legal requirement for your house. Your designer can confirm which rules apply to your building. Source: Ontario 2024 Building Code Compendium, Part 3.
Does this tool design my ramp?
No. It does the arithmetic from the Building Code figures. A real ramp also needs a design for surface, drainage, guards and the exact site, and may need a building permit.