Accessible ramp and doorway calculator (Andare Homes) Inputs: mode=len, units=mm, rise=600 Result: Minimum ramp run: 7,200 mm (283.5 in) - Rise: 600 mm (23.6 in) - Minimum run at 1 in 12: 7,200 mm (283.5 in) - Intermediate level areas (1,700 mm long, at intervals of not more than 9 m): 0 - Level areas at top and bottom: 1,700 mm by 1,700 mm each - Length along the path including all level areas: 10,600 mm (417.3 in) The Building Code allows a maximum gradient of 1 in 12, so the run must be at least 12 times the rise. A gentler slope is allowed and easier to use. The ramp also needs at least 1,000 mm between handrails, with handrails on both sides. Source: Ontario 2024 Building Code Compendium, Part 3, Section 3.8, https://www.ontario.ca/document/2024-building-code-compendium/part-3-fire-protection-occupant-safety-and-accessibility Last checked: 2026-11-08 Tool: https://andarehomes.com/accessible-ramp-and-doorway-calculator/ Free quote: https://andarehomes.com/accessible-ramp-and-doorway-calculator/#page-quote (or https://andarehomes.com/contact/) Preliminary planning only. Section 3.8 does not apply to every house type, so confirm with your designer or the building department.